led display LED light module failure and resolve
Source:MaChen Yushengyuan New energy Co., Ltd.   Time:2012-05-03 15:52:12
led display LED light module failure and resolve
 Phenomenon: all the LED is blinking
 Question: poor contact
 Workaround: loose at re-fixed or patch.

 Phenomenon: the LED dim
 QUESTION: switching power supply and led voltage label inconsistent
 Solution: Make sure the consistency of the switching power supply and LED voltage label

 Phenomenon: the part of the line led light does not shine
 Question: 1. Patch the correct direction
            Two. Power output wiring is correct
            3. Plug the power cord anti then reversed
 Solution: split out, and re-plug in the correct direction
            Make sure the red wire to the cathode, the black wire is connected with negative
            Find out part of the inserted anti-line and connect it again.

 Phenomenon: that all LEDs are lit
 Question: 1. Voltage output switching power supply
            (2) switching power supply output wiring is correct
            Power wiring, the negative is correct

 

jammess